1.
Adv Radiat Oncol ; 9(6): 101499, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38681891

RESUMO

Purpose: To investigate the relationship between normal brain exposure in LINAC-based single-isocenter multitarget multifraction stereotactic radiosurgery or stereotactic radiation therapy (SRT) and the number or volume of treated brain metastases, especially for high numbers of metastases. Methods and Materials: A cohort of 44 SRT patients with 709 brain metastases was studied. Renormalizing to a uniform prescription of 27 Gy in 3 fractions, normal brain dose volume indices, including V23 Gy (volume receiving >23 Gy), V18 Gy (volume receiving >18 Gy), and mean dose, were evaluated on these plans against the number and the total volume of targets for each plan. To compare with exposures from whole-brain radiation therapy (WBRT), the SRT dose distributions were converted to equivalent dose in 3 Gy fractions (EQD3) using an alpha-beta ratio of 2 Gy. Results: With increasing number of targets and increasing total target volume, normal brain exposures to dose ≥18 Gy increases, and so does the mean normal brain dose. The factors of the number of targets and the total target volume are both significant, although the number of targets has a larger effect on the mean normal brain dose and the total target volume has a larger effect on V23 Gy and V18 Gy. The EQD3 mean normal brain dose with SRT planning is lower than conventional WBRT. On the other hand, SRT results in higher hot spot (ie, maximum dose outside of tumor) EQD3 dose than WBRT. Conclusions: Based on clinical SRT plans, our study provides information on correlations between normal brain exposure and the number and total volume of targets. As SRT becomes more greatly used for patients with increasingly extensive brain metastases, more clinical data on outcomes and toxicities is necessary to better define the normal brain dose constraints for high-exposure cases and to optimize the SRT management for those patients.

2.
J Appl Clin Med Phys ; 24(11): e14169, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37775989

RESUMO

PURPOSE: Accurate dose calculation is important in both target and low dose normal tissue regions for brain stereotactic radiosurgery (SRS). In this study, we aim to evaluate the dosimetric accuracy of the two advanced dose calculation algorithms for brain SRS. METHODS: Retrospective clinical case study and phantom study were performed. For the clinical study, 138 SRS patient plans (443 targets) were generated using BrainLab Elements Voxel Monte Carlo (VMC). To evaluate the dose calculation accuracy, the plans were exported into Eclipse and recalculated with Acuros XB (AXB) algorithm with identical beam parameters. The calculated dose at the target center (Dref), dose to 95% target volume (D95), and the average dose to target (Dmean) were compared. Also, the distance from the skull was analyzed. For the phantom study, a cylindrical phantom and a head phantom were used, and the delivered dose was measured by an ion chamber and EBT3 film, respectively, at various locations. The measurement was compared with the calculated doses from VMC and AXB. RESULTS: In clinical cases, VMC dose calculations tended to be higher than AXB. It was found that the difference in Dref showed > 5% in some cases for smaller volumes < 0.3 cm3 . Dmean and D95 differences were also higher for small targets. No obvious trend was found between the dose difference and the distance from the skull. In phantom studies, VMC dose was also higher than AXB for smaller targets, and VMC showed better agreement with the measurements than AXB for both point dose and high dose spread. CONCLUSION: The two advanced calculation algorithms were extensively compared. For brain SRS, AXB sometimes calculates a noticeable lower target dose for small targets than VMC, and VMC tends to have a slightly closer agreement with measurements than AXB.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Encéfalo/cirurgia